Dr Sohini Sengupta and her team’s adoption of Sigma metrics in lab processes had a profound impact on reducing overall Defects Per Million Opportunities (DPMO) and solidifying the dependability of test outcomes.

  Redcliffe Labs, a Pan India omnichannel diagnostics provider, substantially improves lab quality processes by embracing Six Sigma metrics. In a study led by Dr. Sohini Sengupta, Medical Laboratory Director at Redcliffe Labs, her team of experts assessed testing processes to optimize the laboratory’s quality control practices. It translates to fewer errors, fewer sample reruns, and improved turnaround times, bolstering clinician reliance and patient satisfaction.

 

Redcliffe Labs conducted a two-phase quality improvement project with a comprehensive assessment of sigma scores across 25 routine high-volume assay parameters, encompassing 20 clinical chemistry and 5 immunoassay methods. By identifying the parameters with lower sigma scores in the initial phase, i.e., pre-period, they successfully implemented strategic measures to enhance their analytical quality within a rigorous 6-month timeframe. The analysis was performed on the Alinity ci series equipment from Abbott.

 

After the targeted improvements, the team at Redcliffe Labs conducted the post-period analysis to gauge the tangible and positive impact. It included a thorough evaluation of sigma metrics to measure any enhancements in the laboratory’s performance. The average sigma surged significantly from 6.4σ to an impressive 9.2σ. Out of the 25 analytes studied, a substantial 17 exhibited a noteworthy improvement, surpassing the pre-defined threshold of a 1.0 increase in their sigma metric.

 

One of the most notable advancements was observed in Glucose(most commonly tested parameter) showcasing an extraordinary surge from 3.9σ to an exceptional 26.3σ. The increase in the sigma metric for glucose directly correlates to a substantial reduction in the error rate, estimated from 9,224 Defects Per Million Opportunities (DPMO) to less than 1 DPMO, significantly enhancing the reliability of test results.

 

Dr. Sohini Sengupta, Medical Laboratory Director at Redcliffe Labs, said, “The impact of our quality improvement study extends far beyond metrics—it’s a testament to our commitment to excellence. Achieving world-class performance across high-volume assays by adopting Sigma metrics elevates our confidence in our test results. It reiterates our continued focus on achieving the highest standards of quality at Redcliffe. These enhancements also mean fewer errors, efficient workflows, and faster turnaround times.”